BRAND NEW 1,500-LITER FIRE TRUCK A. ENGINE BRAND NEW DIESEL ENGINE 4-CYLINDER CONFIGURATION EURO IV EMISSION COMPLIANT OR BETTER ENGINE DISPLACEMENT: APPROXIMATELY 3,000 CC OR HIGHER MAXIMUM OUTPUT: AT LEAST 124 PS MAXIMUM TORQUE: AT LEAST 36.1 KG-M ENGINE SHALL BE SUITABLE FOR HEAVY-DUTY FIREFIGHTING AND EMERGENCY RESPONSE OPERATIONS. B. CABIN / CREW COMPARTMENT ENCLOSED DRIVING COMPARTMENT WITH SEATING CAPACITY FOR THREE (3) PERSONS. CREW MODULE MOUNTED DIRECTLY BEHIND THE DRIVER'S CABIN. CREW MODULE SHALL PROVIDE FORWARD-FACING SEATING FOR FOUR (4) ADDITIONAL PERSONNEL. TWO-WAY VOICE INTERCOM SYSTEM. CABIN ADEQUATELY INSULATED AGAINST NOISE, VIBRATION, AND TROPICAL TEMPERATURE CONDITIONS. FOUR (4) SERVICE DOORS, WITH TWO (2) DOORS ON EACH SIDE. SERVICE DOORS SHALL HAVE WIDE OPENING ANGLES. DOOR WINDOWS SHALL BE MANUALLY OPERATED. MANUAL CABIN TILT SYSTEM. ALL-STEEL WELDED CONSTRUCTION WITH SAFETY-ZONE DESIGN. HEAVY-DUTY RUBBER FLOOR MATTING. AM/FM RADIO WITH EXTERNAL ANTENNA. C. FUEL TANK FUEL TANK CAPACITY: 100 LITERS OR HIGHER. FUEL TANK MATERIAL: PRESSED STEEL OR EQUIVALENT DURABLE MATERIAL. D. POWER SUPPLY SYSTEM ALTERNATOR: 24V, 90A OR HIGHER. E. DRIVING CONSOLE ONE-KEY ENGINE STARTING/STOPPING SWITCH. LIGHTING SWITCH. DIRECTIONAL INDICATOR, DIMMER, AND PASSING SWITCH. WINDSHIELD WIPER AND WASHER SWITCH. HAZARD LAMP SWITCH. MAP LAMP SWITCH. FOG LAMP SWITCH. WARNING LIGHT SWITCH. WORKING LIGHT SWITCH. HIGH-VISIBILITY GAUGES/METERS. FUEL GAUGE. ENGINE TEMPERATURE GAUGE. SPEEDOMETER WITH TRIP METER. ODOMETER. TACHOMETER. F. WARNING INDICATORS AND ALARMS OIL PRESSURE WARNING LAMP AND BUZZER. ENGINE OVER-RUN WARNING BUZZER. COOLANT LEVEL WARNING LAMP AND BUZZER. HIGH-BEAM INDICATOR. TURN-SIGNAL INDICATOR LAMP. PARKING-BRAKE INDICATOR LAMP. SEAT-BELT WARNING LAMP. EXHAUST-BRAKE INDICATOR LAMP. ENGINE CONTROL SYSTEM WARNING LAMP. REVERSE AUDIBLE ALARM/BACK-UP WARNING BUZZER. CABIN TILT INDICATOR. G. GENERAL BUILT-UP BODY APPARATUS BODY SHELL CONSTRUCTED OF APPROXIMATELY 3.0 MM MILD STEEL PLATE. ALL CABINETRY AND FRAMING CONSTRUCTED OF MILD STEEL. BODY SHALL HAVE RUGGED CONSTRUCTION SUITABLE FOR FIREFIGHTING OPERATIONS. BODY SHALL PROVIDE ADEQUATE VENTILATION AND GOOD VISIBILITY TO THE FRONT, SIDES, AND REAR. ALL HORIZONTAL SURFACES, STEPS, AND TOP DECK SHALL BE COVERED WITH SLIP-RESISTANT CHECKERED ALUMINUM PLATES. ROOF DECK OF THE SUPERSTRUCTURE AND WATER TANK SHALL BE PROVIDED WITH NON-SKID ALUMINUM PLATE, APPROXIMATELY 3.0 MM THICK. STAINLESS-STEEL ACCESS LADDER MOUNTED AT THE REAR PORTION OF THE BODY. PUMP COMPARTMENT LOCATED AT THE REAR PORTION OF THE SUPERSTRUCTURE. LEFT- AND RIGHT-SIDE LOCKERS EQUIPPED WITH LOCKABLE ROLLER SHUTTERS. LOCKERS SHALL HAVE ADEQUATE CAPACITY FOR FIREFIGHTING EQUIPMENT AND ACCESSORIES. ROLLER SHUTTERS SHALL BE CONSTRUCTED FROM ALUMINUM EXTRUDED SLATS WITH FLEXIBLE SEALING BETWEEN SLATS. ROLLER SHUTTERS SHALL HAVE A SECURE LATCHING MECHANISM AND COUNTERBALANCE SYSTEM FOR EASE OF OPERATION. ALL LOCKERS SHALL BE PROPERLY ILLUMINATED. ALL LOCKERS SHALL HAVE DRAINAGE HOLES AT THE BOTTOM. H. PAINTING, FINISHING, IDENTIFICATION AND MARKINGS ALL BODY WELDMENTS, PUMP COMPARTMENTS, AND PIPING SHALL BE PROPERLY INSPECTED AND CLEANED PRIOR TO PAINTING. EXPOSED SEAMS SHALL BE PROPERLY SEALED TO INHIBIT CORROSION. WELDED SURFACES SHALL BE TREATED WITH EPOXY PRIMER. VEHICLE BODY, CAB EXTERIOR, BODY COMPARTMENTS, AND EXPOSED FERROUS METAL SURFACES SHALL HAVE A DURABLE URETHANE PAINT SYSTEM. COLOR SHALL BE STANDARD FIRE-DEPARTMENT RED OR ANOTHER COLOR APPROVED BY THE END-USER. CLEAR-COAT FINISH SHALL BE APPLIED FOR ADDITIONAL PROTECTION. BRIGHT METAL FITTINGS SHALL HAVE CORROSION-RESISTANT PLATED OR EQUIVALENT FINISH. LOGOS AND MARKINGS SHALL BE REFLECTORIZED. MARKING DESIGN AND LOCATION SHALL BE SUBJECT TO END-USER APPROVAL. CONTROL HANDLES, VALVES, AND GAUGES SHALL BE PROVIDED WITH APPROPRIATE IDENTIFICATION/NAME PLATES. I. WATER TANK WATER TANK CAPACITY: 1,500 LITERS. WATER TANK SHALL BE FULLY PROTECTED WITHIN THE VEHICLE SUPERSTRUCTURE. TANK SHALL HAVE PROVISION FOR WATER EXPANSION AND MOVEMENT. TANK MATERIAL: STAINLESS STEEL 304 OR EQUIVALENT. TANK SHELL THICKNESS: 3.0 MM OR THICKER. MANHOLE DIAMETER: APPROXIMATELY 450 MM. MANHOLE SHALL BE SUITABLE FOR FILLING, MAINTENANCE, AND INSPECTION. DRAIN OUTLET LOCATED BEHIND THE REAR AXLE. OVERFLOW PIPING: APPROXIMATELY 2.5 INCHES. WATER-REFILLING PIPING: APPROXIMATELY 2.0 INCHES. WATER-SUCTION PIPING: APPROXIMATELY 4.0 INCHES. WATER-DRAIN PIPING: APPROXIMATELY 2.0 INCHES. LONGITUDINAL BAFFLE SYSTEM SHALL BE PROVIDED TO CONTROL WATER MOVEMENT. BAFFLE PLATES SHALL BE STAINLESS STEEL, APPROXIMATELY 2 MM THICK. BAFFLE ARRANGEMENT: TWO (2) HORIZONTAL AND TWELVE (12) VERTICAL BAFFLES. WATER TANK SHALL BE DETACHABLE AND DESIGNED FOR REMOVAL FROM THE CHASSIS. TANK LEVEL GAUGE: GLASS-TUBE TYPE OR EQUIVALENT. J. FIRE-FIGHTING PUMP PTO-DRIVEN FIRE-FIGHTING PUMP. PUMP SHALL BE SUITABLE FOR HEAVY-DUTY FIRE SUPPRESSION OPERATIONS. TWO-STAGE OR EQUIVALENT LOW- AND HIGH-PRESSURE PUMPING SYSTEM. PUMP SHALL HAVE PRESSURE RELIEF AND THERMAL RELIEF PROTECTION. PUMP SHALL HAVE SELF-FLUSHING FILTRATION SYSTEM. PUMP SHALL HAVE HIGH- AND LOW-PRESSURE IMPELLERS MOUNTED ON A COMMON SHAFT OR EQUIVALENT CONFIGURATION. LOW-PRESSURE RATED PERFORMANCE: AT LEAST 2,000 LPM AT 10 BAR. HIGH-PRESSURE RATED PERFORMANCE: AT LEAST 300 LPM AT 40 BAR. REQUIRED POWER FOR LOW-PRESSURE OPERATION: APPROXIMATELY 67 KW / 90 HP AT APPROXIMATELY 2,980 RPM OR LOWER POWER REQUIREMENT. REQUIRED POWER FOR HIGH-PRESSURE OPERATION: APPROXIMATELY 85 KW / 114 HP AT APPROXIMATELY 2,950 RPM OR LOWER POWER REQUIREMENT. PRIMING PERFORMANCE: MINIMUM RANGE OF 0–7.5 METERS. AUTOMATIC PRIMING SYSTEM. PRIMING SYSTEM SHALL BE CAPABLE OF RELIABLE OPERATION AT SUCTION HEIGHTS OF APPROXIMATELY 8 METERS. PUMP SYSTEM SHALL COMPLY WITH APPLICABLE INTERNATIONAL FIRE-PUMP PERFORMANCE STANDARDS. K. WATER MONITOR AND NOZZLE GEAR-TYPE WATER MONITOR SUITABLE FOR VEHICLE-MOUNTED FIREFIGHTING APPLICATIONS. MONITOR SHALL ALLOW UP/DOWN AND LEFT/RIGHT DIRECTIONAL ADJUSTMENT. NOZZLE SHALL PROVIDE COMBINATION FOG AND STRAIGHT-STREAM PATTERNS. NOZZLE SHALL PROVIDE STABLE FLOW AND EFFECTIVE WATER REACH. NOZZLE MATERIAL: CORROSION-RESISTANT ALUMINUM OR EQUIVALENT. NOZZLE CONNECTION SIZE: APPROXIMATELY 2-1/2 INCHES. FLOW RATE: APPROXIMATELY 350–500 GPM AT 7 BAR. SHOOTING/REACH DISTANCE: APPROXIMATELY 54–56 METERS. NOZZLE WEIGHT: APPROXIMATELY 2.5 KG OR LESS. NOZZLE SHALL HAVE CORROSION-RESISTANT PROTECTIVE FINISH. L. PIPE WORKS ALL PIPE WORKS SHALL BE MANUFACTURED FROM STAINLESS STEEL OR EQUIVALENT CORROSION-RESISTANT MATERIAL. DISCHARGE VALVES SHALL BE STEEL OR EQUIVALENT DURABLE MATERIAL. DISCHARGE CONNECTIONS SHALL USE STANDARD COMPATIBLE FIRE-SERVICE THREADS. PIPE SYSTEM SHALL BE DESIGNED TO ALLOW VALVES AND COMPONENTS TO BE REMOVED WITHOUT DISMANTLING OTHER MAJOR COMPONENTS OR PIPEWORK. M. ELECTRICAL LIGHTS AND WARNING DEVICES ONE (1) MAIN FLASHING LED LIGHT BAR. LIGHT BAR LENGTH: APPROXIMATELY 54 INCHES. SHALL COMPLY WITH APPLICABLE ECE R65 AND/OR SAE J845 STANDARDS. MULTIPLE SELECTABLE FLASH PATTERNS WITH MEMORY FUNCTION. HIGH-INTENSITY LED CONFIGURATION. OPERATING VOLTAGE: 12–24 VDC. DURABLE POLYCARBONATE LENS WITH ALUMINUM OR EQUIVALENT CORROSION-RESISTANT BASE. ADJUSTABLE MOUNTING SYSTEM. SIXTEEN (16) BODY-MOUNTED WARNING LED LIGHTS DISTRIBUTED ON THE SIDES, REAR, AND FRONT. LED WARNING LIGHTS SHALL BE SUITABLE FOR EMERGENCY VEHICLE APPLICATIONS. SHALL COMPLY WITH APPLICABLE ECE AND/OR SAE STANDARDS. MINIMUM INGRESS PROTECTION: IP67. OPERATING VOLTAGE: 12–24 VDC. SYNCHRONIZATION AND ALTERNATING FLASH FUNCTIONS. MEMORY FUNCTION FOR SELECTED FLASH PATTERN. TWO (2) LED WORK LIGHTS WITH APPROXIMATELY 120-DEGREE BEAM/LENS. HEAVY-DUTY MOUNTING BRACKETS. ALUMINUM OR EQUIVALENT DURABLE HOUSING. MINIMUM OF SIX (6) LED ELEMENTS AT APPROXIMATELY 10 WATTS EACH, OR EQUIVALENT ILLUMINATION. OPERATING VOLTAGE: 12–24 VDC. OVER/UNDER-VOLTAGE PROTECTION. REVERSE-POLARITY PROTECTION. POLYCARBONATE OR EQUIVALENT DURABLE LENS. OPERATING TEMPERATURE RANGE SUITABLE FOR TROPICAL AND EMERGENCY-RESPONSE CONDITIONS. LED LIGHTING SHALL BE PROVIDED INSIDE EACH EQUIPMENT LOCKER. PUBLIC ADDRESS SYSTEM WITH MINIMUM 150-WATT AMPLIFIER. OPERATING VOLTAGE: APPROXIMATELY 24V DC. MINIMUM OF EIGHT (8) SELECTABLE SIREN TONES/SOUNDS. TWO-WAY LIGHTING/CONTROL FUNCTION. OPERATING TEMPERATURE: APPROXIMATELY -40°C TO 55°C OR WIDER. ONE (1) 150-WATT SPEAKER COMPATIBLE WITH THE PUBLIC ADDRESS SYSTEM. FIVE (5) EMERGENCY LED PERIMETER LIGHTS. N. SIREN ONE (1) BRAND-NEW ELECTRIC MOTOR SIREN. SUITABLE FOR EMERGENCY/FIREFIGHTING VEHICLE APPLICATIONS. DESIGNED FOR OPERATION ON THE VEHICLE'S ELECTRICAL SYSTEM. O. FIRE-FIGHTING EQUIPMENT TWO (2) PCS. FIREFIGHTING FOG AND STRAIGHT-STREAM NOZZLE, PISTOL-GRIP TYPE, APPROXIMATELY 1.5 INCHES. SIX (6) LENGTHS OF 1.5-INCH X 50-FT DOUBLE-JACKET FIRE HOSE. FIRE HOSE WORKING PRESSURE: 400 PSI OR HIGHER. HOSE COUPLING: 1.5-INCH ALUMINUM NST OR EQUIVALENT STANDARD COUPLING. TWO (2) LENGTHS OF 2.5-INCH X 50-FT DOUBLE-JACKET FIRE HOSE. FIRE HOSE WORKING PRESSURE: 400 PSI OR HIGHER. HOSE COUPLING: 2.5-INCH ALUMINUM NST OR EQUIVALENT STANDARD COUPLING. ONE (1) PC. 1.5-INCH HOSE WRENCH. ONE (1) PC. 2.5-INCH HOSE WRENCH. ONE (1) PC. 2.5-INCH X 1.5-INCH NST REDUCER. ONE (1) PC. CROWBAR. ONE (1) PC. PIKE POLE. ONE (1) PC. BOLT CUTTER. ONE (1) PC. PICK-HEAD AXE. ONE (1) PC. FLAT-HEAD AXE. ONE (1) PC. HALLIGAN-TYPE FORCIBLE-ENTRY BAR OR EQUIVALENT. ONE (1) PC. 16-FT FIBERGLASS EXTENSION LADDER. ONE (1) PC. WYE CONNECTION. ONE (1) SET SUCTION HOSE. ONE (1) UNIT DRY-CHEMICAL FIRE EXTINGUISHER, 10-LB CAPACITY. TWO (2) SETS FIREFIGHTER SUIT CONSISTING OF JACKET AND TROUSERS. FIREFIGHTER SUIT SHALL BE FOUR-LAYER CONSTRUCTION OR EQUIVALENT. FIREFIGHTER SUIT SHALL COMPLY WITH APPLICABLE PPE REQUIREMENTS AND RELEVANT STANDARDS SUCH AS EN 469. SUIT SHALL PROVIDE PROTECTION AGAINST HEAT, FLAME, AND RELATED FIREFIGHTING HAZARDS. TWO (2) PAIRS FIREFIGHTER BOOTS. BOOTS SHALL HAVE STEEL TOE PROTECTION. BOOTS SHALL PROVIDE HEAT RESISTANCE AND SLIP-RESISTANT OUTSOLE. BOOTS SHALL COMPLY WITH APPLICABLE FIREFIGHTER FOOTWEAR STANDARDS SUCH AS EN 15090 OR EQUIVALENT. BOOTS SHALL PROVIDE HEEL SHOCK ABSORPTION AND ANTISTATIC PROTECTION. TWO (2) PAIRS FIREFIGHTER GLOVES. GLOVES SHALL BE MADE OF HEAT-RESISTANT AND ABRASION-RESISTANT MATERIAL. GLOVES SHALL PROVIDE PROTECTION AGAINST HEAT, CUTS, AND MECHANICAL HAZARDS. GLOVES SHALL HAVE REINFORCED PALMS AND KNUCKLE PROTECTION. GLOVES SHALL PROVIDE ADEQUATE DEXTERITY FOR HANDLING FIREFIGHTING EQUIPMENT. GLOVES SHALL COMPLY WITH APPLICABLE FIREFIGHTER GLOVE STANDARDS SUCH AS EN 659 OR EQUIVALENT. TWO (2) PCS. FIREFIGHTER HELMETS. HELMET SHALL COMPLY WITH APPLICABLE FIREFIGHTER HELMET STANDARDS SUCH AS EN 443 OR EQUIVALENT. HELMET SHALL PROVIDE HIGH RESISTANCE TO MECHANICAL IMPACT AND HEAT. HELMET SHALL PROVIDE ELECTRICAL INSULATION PROTECTION. HELMET SHALL HAVE REFLECTIVE MARKINGS FOR VISIBILITY. HELMET SHALL HAVE ADJUSTABLE INTERNAL FITTING. HELMET SHALL HAVE ANTI-SCRATCH AND ANTI-FOG EXTERNAL VISOR. HELMET SHALL HAVE ANTI-SCRATCH AND ANTI-FOG INTERNAL EYE PROTECTION/GOGGLE. FOUR (4) PCS. FIREFIGHTER HOODS/BALACLAVAS. HOOD SHALL BE DOUBLE-LAYER CONSTRUCTION OR EQUIVALENT. HOOD SHALL BE MADE FROM HEAT- AND FLAME-RESISTANT, ANTISTATIC MATERIAL. HOOD SHALL PROVIDE PROTECTION FOR THE HEAD AND NECK. HOOD SHALL HAVE AN OPENING FOR THE EYES AND NOSE WHILE PROVIDING ADEQUATE FACIAL AND NECK COVERAGE. HOOD SHALL COMPLY WITH APPLICABLE FIREFIGHTER PROTECTIVE CLOTHING STANDARDS SUCH AS EN ISO 13911 AND EN 1149-5 OR EQUIVALENT. P. WARRANTY ALL EQUIPMENT, APPARATUS, AND DEVICES SUPPLIED AS COMPONENTS OF THE FIRE TRUCK SHALL HAVE A WARRANTY OF ONE (1) YEAR OR 50,000 KILOMETERS, WHICHEVER COMES FIRST. WARRANTY SHALL COVER APPLICABLE PARTS, SERVICES/LABOR, AND LUBRICANTS FOR THE FIRST PREVENTIVE MAINTENANCE SERVICE. SUPPLIER SHALL PROVIDE WARRANTY SERVICE AND SUPPORT FOR THE COMPLETE FIRE TRUCK AND SUPPLIED FIREFIGHTING EQUIPMENT. Q. TRAINING SUPPLIER SHALL PROVIDE COMPREHENSIVE TWO-DAY OPERATIONAL AND MAINTENANCE TRAINING. TRAINING SHALL BE PROVIDED FOR TWO (2) PERSONNEL PER TRUCK RECIPIENT. TRAINING SHALL COVER PROPER OPERATION, BASIC MAINTENANCE, AND USE OF THE FIREFIGHTING SYSTEMS AND EQUIPMENT. TRAINING VENUE SHALL BE MUTUALLY AGREED UPON BY THE END-USER AND SUPPLIER.
BAC - Goods and Consulting Services/Special BAC
4th Floor, Left Wing, City Investment Hall Building, General Santos City
(083) 552-9435
BAC - Infrastructure
4th Floor, Left Wing, City Investment Hall Building, General Santos City
(083) 552-9435